SEH Configuration Mechanisms
This document is only intended as an addendum to the existing SEH documentation and is not
intended to repeat information already included in SEH documentation. Please refer to the
SEH IPv6 CD for more detailed information and user manuals.
Control Panel
Loading network defaults (DEFAULT NET) from the Zebra printer control panel has no effect
on the SEH IPv6 PS. If you need to reset the network parameters, see Reset the SEH IPv6 PS
to Factory Defaults on page 29.
Parameters for V60.16.x, R6x.16.x, or later Firmware
The following printers and print engines use firmware versions V60.16.x, R6x.16.x, or later:
•105SL
•110XiIIIPlus, 140XiIIIPlus, 170XiIIIPlus, 220XiIIIPlus
•R110XiIIIPlus, R170XiIIIPlus
• Z4Mplus, Z6Mplus
•110PA X 4, 170PA X 4
Firmware Requirements Table 3 shows the network parameters that may be viewed or
modified through the printer’s control panel. These parameters appear on printers with
firmware V60.16.x, R6x.16.x, or later.
Printers with older versions of firmware have a different set of parameters. You may download
firmware V60.16.x, R6x.16.x, or later to access the newer encryption features. Go to
http://www.zebra.com/firmware for firmware download options.
Network Password Some of the parameters can be password-protected by a network
password. By default, the network print servers run in an “unprotected” mode (password set to
0000), which means that you do not need to enter a network password through the control
panel to view or modify network settings. To set a network password (not the same as the
general printer password), use the
^WP ZPL command. For more specific details about ZPL
commands, see ZPL II
®