C.3 Linking Device Usage
The Linking Device is only approved for intended and appropriate use. In case of
non-compliance, the warranty and manufacturer's liability does not apply.
The auxiliary components that meet all requirements of European and national
directives and legislation can be used in potentially explosive atmospheres.
The environmental conditions specified in the manual must be followed strictly.
The Linking Device is not used in systems where cathodic systems for corrosion
protection are in place. Although special precautions may make that possible
(additional earthing bridges), the manufacturer must be consulted in each case.
The operator must provide measures for protection against lightning.
The maximum surface temperatures depend on the circumstances of installing the
equipment, and the customer or operator is responsible for those. During intended
operation no temperature increases of > 20 K are to be reached at the outside parts
of the enclosure. Thus, temperature T4 is maintained.
All outside parts are made from suitable low-sparking materials. However, the
operator must inspect any ignition hazards that may be caused by sparks when
operating the entire machine. Parts containing light metal alloys have to be installed
in a way that they are protected against external impact.
In explosion group IIC and Zone 2 no projected plastic surfaces >20 cm³ are allowed;
in IIB or dust-Ex, 100 cm² may be reached.
Dust settlements must be removed regularly.
The company installing the device must ensure that the transient characteristic is
limited to 40 % above the service voltage.
Icing is not permitted.
C.4 Maintenance and Repair
Definition of terms according to IEC 60079-17:
Maintenance: defines a combination of any actions carried out to retain an item in, or
restore it to, conditions in that it is able to meet the requirements of the relevant
specification and perform its required functions.
Inspection: defines any action comprising careful scrutiny of an item carried out either
without dismantling, or with the addition of partial dismantling as required, supplemented
by means such as measurement, in order to arrive at reliable conclusion as to the
condition of an item.
2PAA114135-610 116
C Linking Device for Zone 2 Explosion and Protection Environment
C.3 Linking Device Usage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB Ability 800xA Series and is the answer not in the manual?

ABB Ability 800xA Series Specifications

General IconGeneral
System TypeDistributed Control System (DCS)
ArchitectureClient-server
RedundancySupports redundant controllers, communication networks, and I/O modules
Operating SystemMicrosoft Windows Server
Communication ProtocolsOPC, Modbus, IEC 61850, PROFIBUS, Foundation Fieldbus
IntegrationSupports integration with third-party systems and ABB products
ScalabilityHighly scalable, from small to large installations
CybersecurityBuilt-in cybersecurity features including access control and network security
User InterfaceGraphical user interface
Application SupportSupports a wide range of industrial applications including process control and safety

Related product manuals