104 E-Clipse Configurations for ACH550 Drives
A
air flow.................................................................... 97
applications
separate drive & bypass run commands......... 18
B
branch circuit protection .........................................87
bypass
contactors, description ...................................95
C
circuit breaker
settings ...........................................................25
construction code ..................................................8
contactor
bypass, description ........................................95
control
connection specifications ...............................96
control panel
control panel tests ..........................................19
features ..........................................................45
cooling ...................................................................97
current
rating code ...................................................... 8
D
digital input
specifications ..................................................96
digital output
specifications ..................................................96
dimensions
mounting ........................................................97
outside, enclosure ..........................................99
DIP switch
location ...........................................................25
settings ...........................................................25
Drive Link Recovery Procedure .............................19
E
e-clipse bypass
diagram ..........................................................7
features, functions ..........................................5
enclosure protection class code ............................8
Energy Saving Estimator Setup ............................43
Energy Savings Estimator .....................................43
F
features
e-clipse-bypass ..............................................5
fuses 87
500...600 volt drives........................................89
G
grounding
requirements ..................................................9
H
heat loss ................................................................97
I
input power
branch circuit protection ................................. 87
fuses ............................................................... 87
input power connection
terminal size ................................................... 89
torque ............................................................. 89
installation
flow chart ........................................................ 7
J
jumper
e-clipse bypass J2, J3 location ...................... 25
L
label
serial number ................................................. 8
type code ........................................................ 8
line reactor ............................................................. 89
location
e-clipse bypass dip sw ................................... 25
e-clipse bypass jumpers ................................. 25
e-clipse bypass pots ....................................... 25
location, mounting ................................................. 9
M
macro
parameter settings for non-e-clipse bypass ....19
manuals ................................................................. ii
motor
rotation direction ............................................. 21
motor connection
terminal size ................................................... 89
torque ............................................................. 89
motor protection
overload relay ................................................. 95
O
O
perating Modes ................................................... 35
overload
pot location ..................................................... 25
relay, motor protection ................................... 95
P
parameter
config for non-e-clipse bypass macro .............19
protection
branch circuit ..................................................87
R
Relay Contact (Digital) Inputs ................................ 38
Relay Contact Outputs .......................................... 39
relays, specifications .............................................. 96
rotation, check direction ........................................ 21
S
safety ..................................................................... 1
serial number ......................................................... 8

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB ACH550 series and is the answer not in the manual?

ABB ACH550 series Specifications

General IconGeneral
EnclosureIP21, IP55
Output Voltage0 to Supply Voltage
Frequency Range0 to 500 Hz
Control MethodScalar control, vector control
Braking ChopperOptional
CommunicationModbus RTU, Profibus, CANopen, Ethernet
Storage Temperature-40°C to +70°C
Relative Humidity5 to 95 % RH, non-condensing
AltitudeUp to 1000 m (derating above 1000 m)
Cooling MethodAir-cooled

Summary

Safety

Use of Warnings and Notes

Explains the types of safety instructions and warning symbols used in the manual.

Installation

Application

Describes the manual as a supplement to the ACH550-UH User's Manual.

E-Clipse Bypass Features and Functions

Lists the key features and functionalities of the E-Clipse Bypass.

Installation Flow Chart

Outlines the sequence of steps for installing the E-Clipse Bypass unit.

Preparing for Installation

Details on drive identification and type code interpretation for installation.

Start-up

HVAC Bypass Control Panel Operation

Explains how to operate the HVAC bypass control panel for start-up.

Start-Up by Changing the Parameters from the Start-Up List

Guides on modifying parameters using the start-up parameter list.

Start-Up by Changing the Parameters Individually from the Parameter List

Details on altering parameters one by one from the full parameter list.

Modes

Describes the different modes accessible via the HVAC Bypass Control Panel.

Parameter Descriptions

Parameter Settings

Information on macro usage for parameter settings.

Parameter Listing

Detailed listing of bypass firmware parameters, their codes, and descriptions.

Embedded Fieldbus and Fieldbus Adapters

EFB Electrical Installation

Covers the electrical installation of the EFB, including DIP switch and terminal connections.

EFB Basic Configuration

Outlines the basic configuration steps for EFB when using the ACH550 drive.

Establishing Bypass Communication

Steps to establish communication between the bypass and a building management system.

Diagnostics and Troubleshooting

Diagnostic Displays

Explains how the bypass reports error situations using LEDs and displays.

Correcting Faults

Recommended actions for addressing detected faults in the bypass system.

Fault Listing

A table detailing fault codes, names, possible causes, and corrective actions.

Alarm Listing

A table listing alarms by code, name, description, possible causes, and actions.

Bypass Status Listing

Details on various bypass status conditions and their meanings.

Error Messages

Lists common error messages and their descriptions for parameter editing.

Technical Data

Input Power Connections

Information on branch circuit protection and fuses for input power.

Fuses

Specifications for drive input fuses across different voltage ranges.

Line Reactor

Information on optional input line reactors for added impedance.

Drive’s Power Connection Terminals

Tables listing wire size capacities and torque for power terminals.

Dimensions and Weights

Mounting dimensions and weights for various enclosure types and frame sizes.

Applicable Standards

Lists standards that the E-Clipse Bypass configuration conforms to.