II F 2-19
3ADW000072R0501_DCS600_System_description_e_e
Aspects of fusing for armature circuits and field supplies of DC drives
Conclusion for the armature supply
Due to cost saving standard fuses are used instead of the
more expensive semiconductor fuses at some applica-
tions. Under normal and stable operating conditions,
this is understandable and comprehensible, as long as
fault scenarios can be ruled out.
In the event of a fault , however, the saving may cause
very high consequential costs. Exploding power semi-
conductors may not only destroy the power converter,
but also cause fires.
Adequate protection against short-circuit and earth
fault, as laid down in the EN50178 standard, is possi-
ble only with appropriate semiconductor fuses.
General
Unit configuration
Protection elements such as fuses or overcurrent trips
are used whenever overcurrents cannot entirely be
ruled out. In some configurations, this will entail the
following questions: firstly, at what point should which
protective element be incorporated? And secondly, in
the event of what faults will the element in question
provide protection against damage?
Fig. 2.6/1 Arrangement of the switch-off elements in the
armature-circuit converter
Aspects of fusing for the armature-circuit and field supplies of DC drives
M
.
.
.
.
.
3
2
2
For field supply
see Fig. 2.6/2
AC supply: public mains / plant's mains
Cabinet
You will find further information in publication:
Technical Guide chapter: Aspects for fusing
Complies with Basic Principles on:
1 – Explosion hazard yes
2 – Earth fault yes
3 – “Hard“ networks yes
4 – Spark-quenching gap yes
5 – Short-circuit yes
6 – 2Q regenerative yes
M M
DCS converter
2-Q non-regen.
Semiconductor
fuses
Semiconductor
fuses
Semiconductor
fuses
4-Q resp.
2-Q regenerative
DCS converter
ABB's recommendations

Other manuals for ABB DCS 600 MultiDrive

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS 600 MultiDrive and is the answer not in the manual?

ABB DCS 600 MultiDrive Specifications

General IconGeneral
BrandABB
ModelDCS 600 MultiDrive
CategoryMedia Converter
LanguageEnglish

Related product manuals