Displays available binary input modules with several binary values per module.
11.3.1.2 Signal matrix for binary input SMBI
Main menu/Test/Binary Input Values/SMT binary inputs/Instance:x
Displays available instances of SMT binary inputs with several inputs per instance.
11.4 View binary output values
11.4.1 Overview
Binary output values show the status of each individual output in the Binary output
module (BOM). If the signal matrix tool is used binary outputs are depicted as
virtual outputs. Note, that only modules installed in the IED are shown in the HMI.
11.4.1.1 Binary Output Module BOM
Main menu/Test/Binary output values/Binary output modules
Displays available binary output modules BOM. The status and name of each
binary outputs that each module has are displayed here. The name of each output is
user defined string. The names of binary outputs are changed in the setting menu.
11.4.1.2 Signal matrix for binary outputs SMBO
Main menu/Test/Binary output values/SMT binary outputs
Displays available sets of binary output values. Each set or instance of binary
outputs displays the status of all individual binary outputs.
11.5 Function test modes
11.5.1 Overview
With the IED, in test mode the different protections (except line differential
protection) can be individually released for test here. Events can be disabled or
enabled.
11.5.2 Differential protection
Main menu/Test/Function test modes/Differential protection
Test of the low and high impedance restricted earth fault protection as well as
transformer differential protection testing.
1MRK504114-UEN E Section 11
Test the IED
75
Operator's manual

Table of Contents

Other manuals for ABB RET670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RET670 and is the answer not in the manual?

ABB RET670 Specifications

General IconGeneral
Rated Frequency50/60 Hz
InputsAnalog and binary inputs
ApplicationProtection of power systems
Communication ProtocolsIEC 61850, DNP3, Modbus
Operating Temperature Range-25°C to +55°C
MountingRack mounted
Number of Binary InputsUp to 48
Number of Binary Outputs32
Protection FunctionsOvercurrent Protection
OutputsBinary outputs
EnclosureIP 54
TypeLine Differential Protection