4.7 Operation without emergency oil supply
If a leak occurs in the emergency oil system during operation and imme-
diate repair is not possible, the turbocharger can be operated without
an emergency oil supply until a repair is possible.
u Remove pipe leading from valve unit or branch to tank.
u Fit blind flange to valve unit or branch.
u Close opening on tank to prevent oil from escaping.
CAUTION
Operation without an emergency oil supply is possible without risk as
long as the lubricating system functions properly during turbocharger
operation.