4 FUNCTION MENU
4.1 NAVIGATING THE MENU
1 2
3 4
Function (1/4)
Mode: Cool
Fast hot water: O
Cool + hot water: Hot water
Heat + hot water: Hot water
Quiet mode: O
This menu is used to set operating functions for the unit. The following keys are
used to navigate this menu:
1. Move back to the previous page;
2. Move on to the next page;
3. Go back to the higher level menu;
4. Go back to the main page;
To access a function, click on the text of that function.
Note:
While navigating the menu pages, the current page of the selected menu will
be displayed in the header (i.e. in the darker upper area);
Any functions not available will be highlighted by the letters “NA.
4.2 SETTING THE OPERATING MODE (MODE)
Mode
Heat Heat + Hot water
Hot water Cool
Cool + hot water
OK Cancel
After accessing the “Mode function, you can choose one of the modes available by
clicking directly on the text that identies it and then conrming with the ”OK” key.
Note:
1. Before changing the operating mode, the unit must be OFF, otherwise a mes-
sage will warn you to turn the unit o before changing the mode;
2. If the compatible Aermec accessory tank for this model (refer to the installation
manual for more information) is not installed and correctly set, the only modes
available will be HEATING and COOLING;
3. If the relative function is activated (paragraph "8.3Activating/deactivating the
memory (On/o memory)p.25"), the value of this parameter will be stored
in the memory and automatically reset after any possible voltage failure;
4. The default value for this parameter is: “Heat.
4.3 ACTIVATING THE FUNCTION FOR FAST DOMESTIC HOT
WATER PRODUCTION (FAST HOT WATER)
Fast hot water
On
O
OK Cancel
After accessing the “Fast hot water” function, you can choose whether to activate
- along with the unit compressor - the electric heater inserted in the compatible
Aermec accessory tank (specic for this model) for the production of domestic hot
water. To activate this function, click directly on “ON” and then conrm with “OK”.
Note:
1. If the compatible Aermec accessory tank for this model (refer to the installation
manual for more information) is not installed and correctly set, this function
will not be available;
2. To ensure even better energy saving, it is advisable to disable this function;
3. If the relative function is activated (paragraph "8.3Activating/deactivating the
memory (On/o memory)p.25"), the value of this parameter will be stored
in the memory and automatically reset after any possible voltage failure;
4. The default value for this parameter is: “O.
4.4 SETTING THE PRIORITY BETWEEN COOLING AND
DOMESTIC HOT WATER PRODUCTION (COOL+HOT
WATER)
Cool + hot water
Hot water
Cool
OK Cancel
After accessing the Cool+hot water” function, you can select “Cool” to force the unit
to rst of all satisfy the system terminal side; by selecting “Hot water”, priority is giv-
en to domestic hot water production. Select the priority, then press “OK” to conrm.
Note:
1. If the compatible Aermec accessory tank for this model (refer to the installation
manual for more information) is not installed and correctly set, this function
will not be available;
2. If the relative function is activated (paragraph "8.3Activating/deactivating the
memory (On/o memory)p.25"), the value of this parameter will be stored
in the memory and automatically reset after any possible voltage failure;
3. The default value for this parameter is: “Cool”.