7 TROUBLESHOOTING
The problems, possible causes and remedies listed below are only a guide and guidance
should be sought from your local dealer or Garnett Farms Engineering Ltd if you are
unsure at any point.
Problem
Possible cause
Remedy
The machine has no power.
Isolator is turned off.
Turn the isolator on.
(See Section 1.2.5)
Battery is flat.
Charge the battery.
(See Section 4.1)
Reset button has not been
pressed after power up.
Press Reset Button.
(See Section 1.2.7)
Circuit breaker has
tripped.
Reset the circuit breaker.
(See Section 4.4.3)
Emergency stop button
has been pressed.
Reset emergency stop.
(See Section 1.2.7)
Parking brake not holding.
Tyre pressure low.
Inflate tyre.
(See Section 3.2)
Insufficient bedding is being
dispensed.
Gap in the metering
shutter is too small.
Open the metering shutter to
suit the bedding in use.
(See Section 4.3.1)
Auger is not running fast
enough.
Increase the auger speed.
(See Section 4.3.2)
Conveyor is not running
fast enough.
Increase the conveyor speed.
(See Section 4.3.2)
Too much bedding is being
dispensed.
Gap in the metering
shutter is too big.
Close the metering shutter to
suit the bedding in use.
(See Section 4.3.1)
Auger is running too fast.
Reduce the auger speed.
(See Section 4.3.2)
Conveyor is running too
fast.
Reduce the conveyor speed.
(See Section 4.3.2)