Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017 71
Configuring the Drive in a Logix System Chapter 3
9. Click Load/Store.
The Nonvolatile Memory Load/Store dialog box appears.
10. From the Automatic Firmware Update pull-down menu, choose Enable
and Store Files to Image.
11. Click <-- Store.
Two confirmation dialog boxes open that relate to communication
disruptions and erasure of the current contents of the storage card.
12. If okay, click Yes on either dialog box.
The programming software goes to the Offline state, and this dialog
box appears.
13. Wait for the store operation to complete, and then attempt to go online
with the controller again.
Using Automatic Device
Configuration (ADC)
Automatic Device Configuration (ADC) is a Studio 5000 - Logix Designer
application feature that supports the automatic download of drive
configuration data. When the RSLogix 5000 software controller establishes an
I/O connection with a drive and its associated peripherals, it checks a
configuration signature for each port. This is to determine if an ADC
download is needed. The purpose is to reduce downtime in a field replacement
situation by automatically downloading the configuration rather than
manually with a separate tool.
ADC is available with the following software:
• Studio 5000 - Logix Designer, Version 21 or later
• RSLogix 5000, Version 20
• PowerFlex 755T AOPs, Version 1.xxx or later