80 Rockwell Automation Publication 750COM-UM009A-EN-P - May 2017
Chapter 3 Configuring the Drive in a Logix System
Method 1
1. Connect via the Ethernet by using a second configuration tool, such as
Connected Component Workbench (CCW).
2. Change any unused parameters in the drive and/or peripheral ports.
Note the parameter value before and after your change. It is the initial
parameter write that causes the Configuration Signature to clear for a
particular port.
3. Reset the drive from the tool.
ADC triggers and executes.
4. Check the parameter that you changed to verify it has changed back to
the original setting.
Method 2
1. If a HIM is present and the port it resides in Port 1 is not write
protected, use the HIM to change any unused parameter in drive /
peripheral. It is the initial parameter write that causes the Configuration
Signature to clear for a particular port.
2. Reset (similar to step 3).
ADC triggers and executes.
3. Check the parameter that you changed to verify it has changed back to
the original setting.
Monitoring ADC Progress
The time that it takes for the Firmware Supervisor, ADC, and connection
process to complete varies from seconds to several minutes depending on
several factors.
Whether Firmware Supervisor is enabled and must upgrade the drive
and/or any peripherals before ADC occurs. Updating drives or
peripherals add significantly to the connection process time and is
similar to the time it takes to update manually using ControlFLASH
software.
The number of peripherals that are enabled for ADC.
If a configuration signature, for the drive/peripheral, indicates that a
configuration download must be performed for the given port.
If a 20-750-S1 option module, which requires a manual step in its
configuration process, is used.
The number of drive resets required for ports with configuration
parameters require a reset to become active.

Table of Contents

Other manuals for Allen-Bradley PowerFlex 755T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 755T and is the answer not in the manual?

Allen-Bradley PowerFlex 755T Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 755T
CategoryAdapter
LanguageEnglish

Related product manuals