OPERATION
Vector™ H Serie s ▪ S ervice M an ual ▪ MN-4 6 543 ▪ R ev 01 ▪ 11/ 1 9
14
How to Update the Control Board (CB)
Before you begin ▪ The chambers should be off (not preheated).
▪ Do not remove the USB drive during the update process.
▪ You will need a USB drive with the updated firmware.
▪ You will need to know the service pass code.
Procedure To update the control board, do the following.
Step Action
1. Touch the gear icon a. The User Configuration screen displays.
2. Touch the USB icon b. The USB Functions screen displays.
3. Plug the USB drive into the port c.
Continued on next page
NOTICE
Do not remove the USB drive during the update
process.