TESTING
Ve ct or™ H Se ries ▪ S ervice Ma nual ▪ MN -4 6 54 3 ▪ R ev 01 ▪ 11/ 19
71
How to Calibrate a Chamber Thermocouple
Before you begin ▪ The oven must be connected to electric power.
▪ Make sure the chamber’s are in an OFF state.
▪ Make sure you have a multimeter with thermocouple attachment.
▪ Make sure the jet plates are installed.
▪ You will need to know the service pass code.
Procedure To calibrate a chamber thermocouple, do the following.
Step Action
1. Insert the multimeter’s thermocouple into the chamber corresponding to the
oven thermocouple that needs calibrating.
2. Touch the chamber icon a.
Touch the Set Temp icon b. The Enter Temperature screen displays.
Enter a temperature of 450°F (232°C) c using the number pad.
Touch the green check mark d. The oven starts the preheat process.
3. Record the following after the oven has finished preheating:
▪ Temperature of the selected chamber.
▪ Temperature from the multimeter.
4. Touch the gear icon e. The User Configuration screen displays.
Continued on next page