Introduction
asafeinstall_dgb, AutroSafe Interactive Fire Detection System, Release 4,
116-P-ASAFE-INSTALL/DGB, Doc-1004796-2, 2021-08-23, Autronica Fire and Security AS
Page 4
7. Power Consumption ........................................................ 32
7.1 Mains Power ...................................................................................... 32
7.1.1 STX Power .............................................................................. 32
7.1.2 BPS-410 .................................................................................. 32
7.2 System Units ..................................................................................... 32
7.3 Loop Units ......................................................................................... 32
7.4 Phoenix Ethernet Switches ............................................................... 33
8. Cable Connection Overview ............................................ 34
9. Connecting Internal Cables ............................................. 35
9.1 Overview – BS-420 / BC-420 ............................................................ 35
9.2 BS-420 / BC-420 ............................................................................... 36
9.2.1 AL_Com+ Connection on Controller Board BSA-400 ............. 36
9.2.2 AL_Com+ Connection on Communication Module BSL-310 .. 36
9.2.3 Multifunction Serial Port Connection on Controller Board
BSA-400 .................................................................................. 36
9.2.4 Multifunction Serial Port Connection on Terminal Block,
List L1 ...................................................................................... 37
9.2.5 Multifunction Serial Port Connection Overview – BSA-400 .... 37
9.3 BC-440 .............................................................................................. 38
9.4 Internal Earth Cabling ........................................................................ 38
10. Connecting External Cables ........................................... 39
10.1 Introduction ........................................................................................ 39
10.2 Before Connecting Cables ................................................................ 39
10.3 Cyber Security ................................................................................... 39
10.4 Mains Wiring - Two-pole Disconnect Device ..................................... 39
10.4.1 115/230VAC Voltage BPS-410 ............................................... 40
10.5 AutroFieldBus Connections ............................................................... 40
10.5.1 Connections to BS-420/BC-420 - Terminal Block (List 1)....... 40
10.5.2 Connections to Connector J2, Power Board BSF-400 ........... 41
10.5.3 Example of the Interconnection of Several Power Cabinets .. 41
10.6 Connection of Network Cables (AutroNet) ........................................ 42
10.6.1 AutroNet Redundant Star Topology ........................................ 42
10.6.2 AutroNet Single Star Topology ............................................... 43
10.6.3 AutroNet Ring Topology .......................................................... 44
10.6.4 Connection to Controller Board BSA-400 ............................... 45
10.6.5 Common Earth Connections ................................................... 45
10.7 RS-485 Connections to Terminal Block, List L1 ............................... 46
10.8 RS-422 Connections to Terminal Block, List L1 ............................... 46
10.9 RS-232 Connections to Terminal Block, List L1 ............................... 46
10.10 24V Power Connections .................................................................... 47
10.10.1 Connections to Controller Board BSA-400A ........................ 47
10.10.2 Connections to Power Board BSF-400 ................................ 48
10.10.3 Power Connection Overview ................................................ 49
10.11 Mains Power Connections................................................................. 50
10.11.1 Power Cabinet STX .............................................................. 50
10.11.2 Power Supply BPS-410 ........................................................ 50