9.1.2 Function
Fig.28:
Alubrication startsat thefirst connection.
Thered andthe green LEDin the controlunit windowglowfor 1,5sec. when voltage(ignition) is activated.
If the voltage is interrupted during the cycle process or the lubrication duration (switch off ignition), data are saved in data
memoryof controlunit. Cycle processstarts againfromwhere ithas been interrupted,when voltage isactive again.
An intermediate lubrication can be initiated at any time by pressing the button for intermediate lubrication. The current
cycledata aredeleted and alubrication immediately starts.
Some errors have to be reset by pressing the intermediate lubrication button. The pump immediately starts with a
lubrication.
Switch to set
lubrication time
Switch to set cycle time
Connection
for voltage connection
Hirschmann 7-poles
GO070WF
Connection plug
for add on equipment
Hirschmann 7-poles
GO610WF
Intermediate lubri. button
Label
LEDs for functional
display
Connection of
system diagnose