The control unit connection is done via the left Hirschman plug (see Fig. 28 or 10.3.3 Connection plan for the central
lubrication pump PICO with integrated control unit PICO-tronic). Cable, relay, lamp etc. are not included in the scope of
delivery.
The control unit is delivered with the setting „error signal“ by default. If you want to use the setting „OK signal“, you can
indicatethis whenordering or changeit by meansof theBEKADiSyssoftware (currentverionon BEKAwebsite).
9.8 Special function „adaption to operating conditions“
30 seconds after activate voltage, you can select the „adaption to operating conditions“ via
the3-step switch.
Operating conditions:
Normal - Normalload: all lubepoints receive lubricantwith setintervals.
Fig.40:
Light - Lightload: lube pointsreceive lubricant inlonger intervals
Fig.41:
Heavy duty -Heavy duty: lubepoints receive lubricantin shortintervals
Fig.42:
When actuating the 3 step switch, the ignition shall be switched on and off or an intermediate lubrication shall be initiated
(seefig. 29).
If the special function „ “ is used, the function „adaption to operation conditions cycle locked“ is
not possible.
lubrication duration
cycle duration 100 %
z. B. 2 h
lubrication duration
cycle duration 125 %
z. B. 2,5 h
lubrication duration
Cycle time 75 %
z. B. 1,5 h
Fig. 39: