Pump is not switched off
despite reservoir is empty
level switch defective
exchange control unit
integrated control unit defective exchange control unit
pulse error at operating mode
cycle control pulse-dependent
change pos. defect external signal
transmitter or broken cable
pulse error available in operating
mode lubrication pulse-dependent
exchange possible broken proximity
switch at distributor or the
broken cable, perform an intermedi.
lubrication 1-2 times
cycle locked pump is temporarily out of order
LED in control unit window of
control unit blinks
pump lubricates no error (see 12.2 or 12.3
blink signals...)
Error „lubrication deficit“ available no error; perform an intermedi.
lubrication 1-2 times
Error „line rupture available Renew line, retight fitting or
exchange it
Error „level error“ available
Fill up reservoir
„Error system pressure“ available
Check system and repair it
if necessary
„Error speed monitoring“ available Check system / pump and repair
it if necessary
Operating mode or setting
of control unit has been changed but
the old label was not replaced
with the new one
Perform a diagnose
by means of BEKA-DiSys software
and have the setting correct
acc. to the label or change the label
Function of pump (operating mode,
cycle duration or lubrication
duration) do not match the set
values in the control unit window
Error
possible cause
possible remedy