1 689 988 238 2012-11-06| Robert Bosch GmbH
86 | ACS 651/751 | Commissioningen
i If the message Calibration Check OK is dis-
played, the calibration check is complete and the refrig-
erant tank cylinder does not require calibration.
7. Press E.
8. Press c thrice to return to the main menu.
"You have successfully checked if the refrigerant tank
scale is accurate.
i If the message Calibration Check NOK is dis-
played, the refrigerant tank sensor has to be calibrat-
ed. Contact customer service to perform calibration.
4.6 Refrigerant tank scale calibration
check
The refrigerant tank scale is calibrated at the factory.
You can perform a calibration check to determine the
accuracy of the R134a scale.
i Before performing the calibration check, ensure
that the ACS 651/751 is positioned on a horizontal,
vibration-free surface.
1. In the main menu select "ACS Maintenance".
2. Select "Maintenance" "R134a Calibration
Check".
3. Select "Start Calibration Check".
4. Attach the calibrating weight (Fig. 24, Pos. 2) to the
neck (Fig. 24, Pos. 1) of the R134a cylinder.
459897_42Nkv
2
1
Fig. 24: Attaching the standard calibrating weight to the cylinder
neck
i The part number of the weight is F 002 DG3 4RD.
5. Select "Place Standard Weight".
6. The option "Calibration Check" is automatically
selected.

Table of Contents

Other manuals for Bosch ACS 751

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch ACS 751 and is the answer not in the manual?

Bosch ACS 751 Specifications

General IconGeneral
BrandBosch
ModelACS 751
CategoryService Equipment
LanguageEnglish

Related product manuals