7. ADJUSTMENT
7-19. Adjusting the needle up stop home position
4700Q
h
Needle plat
O!CAUTION
-
•
-
H
T---o:::;::===-...____
o
lvv·SCALE
oE}sPEED
0
.l
SPRITNo. -
&:;:®
®!
-88888
4699Q
1. Remove the needle, the needle bar thread guide and
the feed plate.
2. Tum the
pulley
to
move the needle bar {1) to the lowest
position.
3. Remove the rubber cap {2) from the face plate, and
then loosen the screw (3) of the needle bar clamp.
4. Adjust so that the distance h is as shown below when
the needle bar is at its lowest position.
5. Tighten the screw (3), and then
install the rubber cap
(2).
6. Tum the machine pulley
to
lower the needle bar (1)
from its highest position to height
H.
Needle
0Px17
0Px5
KE-4300
I
BE-4380
H
52.7
mm
I 53.87mm
47.6
mm
h 18.0
mm
12.9mm
4701Q
7. While pressing the
1:1
key (4), tum on the power switch.
• Keep pressing the
1:1
key {4) until the model name is displayed and the buzzer beeps once.
8. Press the
1:1
key {4) or V key {5) to select check code • 8
".
(Refer to "2-9. Input checking method".)
9. Release the machine
pulley and loosen the bolt (7) of the magnet (6) by 1/4
of
a tum.
10. Move the magnet (6) to the point where the menu display {7) changed
from·
on"
to
"oFF", and then tighten the bolt (7).
78