SETUP, Cont.
DIGITAL FILL CONTROL TARE
A new prompt tArE= has been added following the dFC (Digital Fill Control) prompt. It
is used to determine whether the fill operation is a Net or Gross weight operation. If the
YES is selected for tArE=, then the operation will be a Net fill operation. The weight on
the scale will be “tared” (not included in the total), then the fill operation will begin. If the
NO is selected for tArE=, then the operation will be a Gross fill operation. The fill
operation will begin with the weight on the scale included in the total.
Press the ENTER key to show the current value. If the setting displayed is acceptable,
press the ENTER key again to save it. Otherwise, using the numeric keys, 0 (NO) or 1
(YES), enter the new setting, then press the ENTER key to save it.
Tare=yes Tare=no
Net fill operation Gross fill operation
TRUCK STORAGE
The trSto= prompt and Truck Storage feature has been removed.
OPERATION
SINGLE SPEED OPERATION
This method of the 748P Digital Fill Control fills one ingredient up to a Preset Target
weight limit minus a stored Trim weight. It controls a single relay (preset #1) to fill at one
rate (fast).
Note that this Digital Fill Control feature must have been set to a “1” during
setup and calibration of the 748P to be operational
.
To start a fill operation:
1. With the indicator in the Gross Weight mode (the Gross annunciator on), press
the PRESET key.
2. The display will change to fill=, the prompt for the stored Target Weight. Press
the ENTER key to show the current value. If the setting displayed is
acceptable, press the ENTER key again to save it. Otherwise, using the
numeric keys, enter the target weight and press the ENTER key. Note, the
target weight is stored in non-volatile memory.
3. The display will change to tr=, the prompt for the stored Trim Weight. Press
the ENTER key to show the current value. If the setting displayed is
acceptable, press the ENTER key again to save it. Otherwise, using the
numeric keys, enter the trim weight and press the ENTER key. Note, the trim
weight adjusts automatically and like the target weight is stored in non-volatile
memory.