Document revision history
RTU Open v3 CARRIER CORPORATION ©2019
Installation and Start-up Guide All rights reserved
108
Important changes to this document are listed below. Minor changes such as typographical or formatting errors are not
listed.
Date
Topic
Change description
Code*
2/23/17
Specifications
Wireless sensor overview
To install the Wireless Adapter for
wireless sensors
Wiring devices to the RTU Open's
Rnet port
Input wiring specifications
Changed WS to wireless.
C-D
1/23/17
Startup Wizard
Correction - Property is always displayed in the Startup Wizard
C-AE-BR-E
Sequence of operation - Linkage air
source mode determination
Clarified reason and method for generating a particular mode.
Evacuation/Shutdown changed to Evacuation.
C-AE-WB-E
ZS sensor overview
SPT sensor overview
Simplified. Detailed descriptions are available in specified
manuals. Corrected total number of ZS sensors.
C-AE/TS-RD/WB-
O
Wireless sensor overview
To install the Wireless Adapter for
wireless sensors
New Topics
C-D
Wiring devices to the RTU Open's
Rnet port
Added Wireless Adapter for wireless sensors
C-D
Input wiring specifications
Added Wireless Adapter for wireless sensors
C-D
To wire the controller to the
network
Added BACnet ARC156 connection information
C-D
Wiring for communications
Changed from Wiring the RTU Open to the MS/TP network
C-D
Specifications
Added BACnet ARC156 connection and Wireless Adapter for
Carrier wireless sensors. Corrected SPT information.
C-D
11/23/16
Sequence of Operation - Linkage
Added Linkage system safety override for Heating Mode.
C-TS-WB-E-JN
2/24/16
Sequence of Operation - Indoor Air
CO2
This section erroneously left out - reinserted.
C-TS-CB-E-WB
Start-up
Added USB Link wiring caution.
C-TS-RD-E-JH
12/3/15
What is the RTU Open?
Note that metric version is available.
C-AE-WB
Sequence of Operation
Indoor Air CO2 section deleted because same as Space Air
Quality.
C-TS_RR_E
Service Test
Correction - Service Test cannot be turned on or off from an
Equipment Touch.
C-TS-RR-E
Wiring and mounting the
Equipment touch
Corrected the external 10 kOhm, Type II thermistor number
from 33ZCT57SPT to 33ZCT55SPT
C-TS-PH
* For internal use only

Table of Contents

Other manuals for Carrier RTU Open v3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier RTU Open v3 and is the answer not in the manual?

Carrier RTU Open v3 Specifications

General IconGeneral
BrandCarrier
ModelRTU Open v3
CategoryController
LanguageEnglish

Related product manuals