Fabric Module LEDs
StatusColorLED
All diagnostics pass. The module is operational (normal initialization
sequence).
GreenStatus
Indicates one of the following:
• The diagnostic test has failed. The module is not operational
because a fault has occurred during the initialization sequence.
• An over temperature condition has occurred. (A major temperature
threshold has been exceeded during environmental monitoring.)
Flashing
Red
The module has detected a slot ID parity error and will not power on
or boot up.
Red
The fabric module is not receiving power.Off
The operator
has has
flagged this
module for
identification.
Flashing blueID
This module is not being identified.Off
Fan Tray LEDs
StatusColorLED
The fan tray is operational.GreenSTATUS
One or more fans is running below the threshold speed.
The fan tray is receiving insufficient power.
Flashing red
No power is going to the fan tray.Off
The operator has activated this LED to identify this module in the chassis.
Flashing blueID
This module is not being identified.Off
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.196
LEDs
Fabric Module LEDs