3 N77-AC-3KW 539 W 3000 W Ok
Actual Power
Module Model Draw Allocated Status
(Watts ) (Watts )
------- ------------------- ----------- ----------- --------------
2 N77-M348XP-23L 429 W 560 W Powered-Up
3 N77-M348XP-23L 430 W 560 W Powered-Up
4 N77-M348XP-23L 428 W 560 W Powered-Up
5 N77-SUP3E 100 W 190 W Powered-Up
6 supervisor N/A 0 W Absent
7 N77-F430CQ-36 604 W 1000 W Powered-Up
9 N77-M348XP-23L 430 W 560 W Powered-Up
Xb1 N77-C7710-FAB-3 58 W 85 W Powered-Up
Xb2 N77-C7710-FAB-3 60 W 85 W Powered-Up
Xb3 N77-C7710-FAB-3 59 W 85 W Powered-Up
Xb4 N77-C7710-FAB-3 61 W 85 W Powered-Up
Xb5 N77-C7710-FAB-3 61 W 85 W Powered-Up
fan1 N77-C77xx-FAN 37 W 900 W Powered-Up
fan2 N77-C77xx-FAN 37 W 900 W Powered-Up
fan3 N77-C77xx-FAN 37 W 900 W Powered-Up
N/A - Per module power not available
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured) PS-Redundant
Power Supply redundancy mode (operational) PS-Redundant
Total Power Capacity (based on configured mode) 45000 W
Total Power of all Inputs (cumulative) 48000 W
Total Power Output (actual draw) 8658 W
Total Power Allocated (budget) 13990 W
Total Power Available for additional modules 31010 W
Clock:
----------------------------------------------------------
Clock Model Hw Status
----------------------------------------------------------
A Clock Module -- NotSupported/None
B Clock Module -- NotSupported/None
Fan:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Fan1(sys_fan1) N77-C77xx-FAN 1.1 Ok
Fan2(sys_fan2) N77-C77xx-FAN 1.1 Ok
Fan3(fab_fan3) N77-C77xx-FAN 1.1 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- Ok
Fan_in_PS3 -- -- Ok
Fan Zone Speed: Zone 1: 0x57
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
1 Crossbar1(s1) 125 115 48 Ok
1 Crossbar2(s2) 125 115 61 Ok
1 Arb-muxSn0(s3) 125 105 56 Ok
1 Arb-muxSn1(s4) 125 105 58 Ok
1 CPU (s5) 125 105 54 Ok
1 CPU (s6) 125 105 54 Ok
1 PCISW (s7) 110 100 46 Ok
1 L2L3Dev1Sn1(s8) 125 115 60 Ok
1 L2L3Dev1Sn2(s9) 125 115 66 Ok
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.54
Managing the Switch
Displaying Environmental Information for a Switch

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Nexus 7710 and is the answer not in the manual?

Cisco Nexus 7710 Specifications

General IconGeneral
BrandCisco
ModelNexus 7710
CategorySwitch
LanguageEnglish

Related product manuals