Full Redundancy
Mode
Input Source
Redundancy
Mode
Power Supply
Redundancy
Mode
Combined ModePower SuppliesPower Inputs
—
——3500 W11 input (220/230
V)
3500 W3500 W3500 W7000 W2
3500 W3500 W7000 W10,500 W3
7000 W7000 W10,500 W14,000 W4
7000 W7000 W14,000 W17,500 W5
10,500 W10,500 W17,500 W21,000 W6
10,500 W10,500 W21,000 W24,500 W7
14,000 W14,000 W24,500 W28,000 W8
—
——3100 W11 input (210 V)
3100 W3100 W3100 W6200 W2
3100 W3100 W6200 W9300 W3
6200 W6200 W9300 W12,400 W4
6200 W6200 W12,400 W15,500 W5
9300 W9300 W15,500 W18,600 W6
9300 W9300 W18,600 W21,700 W7
12,400 W12,400 W21,700 W24,800 W8
—
——1500 W11 input (110 V)
1500 W1500 W1500 W3000 W2
1500 W1500 W3000 W4500 W3
3000 W3000 W4500 W6000 W4
3000 W3000 W6000 W7500 W5
4500 W4500 W7500 W9000 W6
4500 W4500 W9000 W10500 W7
6000 W6000 W10500 W12000 W8
A combination of 3-kW AC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.80
Managing the Switch
Maximum Power Available for 3.5-kW Inputs (AC)