SiUS091133 Indoor Unit: FTXS30/36LVJU
Removal Procedure 232
3.4 Removal of PCBs
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the signal
receiver PCB.
1
Unfasten the hooks of
the shield plate.
2
Open the shield plate. The shield plate has 2 hooks at
the lower part also.
3
Remove the shield
plate.
(R9506)
Shield
plate
(R9507)
(R9508)
Hook
(R9509)