Typical operating curve
0
0
Q max
Pressure
Fl
ow
P101 166E
PC setting
Simple closed center circuit
P101 965
Once the closed center valve is opened, the PC control senses the immediate drop in system pressure
and increases pump flow by increasing the swashplate angle.
The pump continues to increase flow until system pressure reaches the PC setting.
If system pressure exceeds the PC setting, the PC control reduces the swashplate angle to maintain
system pressure by reducing flow. The PC control continues to monitor system pressure and changes
swashplate angle to match the output flow with the work function pressure requirements.
If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum
displacement. In this condition, actual system pressure depends on the actuator load.
For additional system protection, install a relief valve in the pump outlet line.
Pressure compensated system characteristics
Constant pressure and variable flow
High pressure standby mode when flow is not needed
System flow adjusts to meet system requirements
Single pump can provide flow to multiple work functions
Quick response to system flow and pressure requirements
Typical applications for pressure compensated systems
Constant force cylinders (bailers, compactors, refuse trucks)
On/off fan drives
Drill rigs
Sweepers
Trenchers
PVPC adapter for external pilot oil supply
PVPC with check valve for open center PVP
PVPC with check valve is used in systems where it is necessary to operate the PVG 32 valve by means of
the electrical remote control without pump flow. When the external solenoid valve is opened, oil from
the pressure side of the cylinder is fed via the PVPC through the pressure reducing valve to act as the
pilot supply for the electrical actuators. This means that a load can be lowered by means of the remote
control lever without starting the pump.
The built-in check valve prevents the oil from flowing via the pressure adjustment spool to tank. With the
pump functioning normally the external solenoid valve is closed to ensure that the load is not lowered
Technical Information
PVG 32 Proportional Valve Group
Function
18 |
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals