Fluids parameters
Oil viscosity
*
recommended range 12 - 75 mm²/s [65 - 347 SUS]
minimum 4 mm²/s [39 SUS]
maximum 460 mm²/s [2128 SUS]
Oil temperature recommended range 30 - 60˚C [86 -140˚F]
minimum -30˚C [-22˚F]
maximum 90˚C [194˚F]
Ambient temperature recommended range -30° → 60°C [-22° → 140°F]
Filtering in the hydraulic system Max. allowed degree of contamination: 23/19/16
(ISO 4406, 1999 version)
*
Max. start up viscosity 2500 mm²/s.
PVPX, electrical LS unloading valve
PVPX technical data
Max. operating pressure
350 bar [5075 psi]
Enclosure to IEC 529
IP65
Max. pressure drop at an oil flow of 0.1 l/min [2.6 US gal/min]
2 bar [30 psi]
Oil temperature
(Inlet)
Recommended temperature
30 °C to 60 °C [86 °F to 140 °F]
Min. temperature
-30 °C [-22 °F]
Max. temperature
90 °C [194 °F]
Max. coil surface temperature
155 °C [311 °F]
Ambient temperature
-30 °C to 60 °C [-22 °F to 140 °F]
Oil viscosity Operating range
12 to 75 mm
2
/s [65 to 347 SUS]
Min. viscosity
4 mm
2
/s [39 SUS]
Max. viscosity
460 mm
2
/s [2128 SUS]
Response time for LS pressure relief
300 ms
Rated voltage
12 V 24 V
Max. premissible deviation from rated supply voltage
± 10%
Current consumption at rated
voltage
at 22 °C [72 °F] coil temperature
1.55 A 0.78 A
at 110 °C [230 °F] coil temperature
1 A 0.5 A
Power consumption at 22 °C [72 °F] coil temperature
19 W
at 110 °C [230 °F] coil temperature
12 W
Technical Information
PVG 32 Proportional Valve Group
PVG 32 technical data
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802 | 29