PVLA, suction valve (fitted in PVB)
PVLA, suction valve
Symbol Description Code number
Suction valve for port A and/or B. 157B2001
Plug for connecting the nonactive port to tank, when using a
single acting spool.
157B2002
PVLP, shock and suction valve (fitted in PVB)
PVLP, shock/ and anti-cavitation valves
Code no.
157B....
2032 2050 2063 2080 2100 2125 2140 2150 2160 2175 2190
Settings bar 32 50 63 80 100 125 140 150 160 175 190
[psi] [460] [725] [914] [1160] [1450] [1813] [2031] [2175] [2320] [2538] [2755]
Code no.
157B....
2210 2230 2240 2250 2265
2280
2300 2320 2350 2380 2400
Settings bar 210 230 240 250 265 280 300 320 350 380 400
[psi] [3045] [3335] [3480] [3625] [3845] [4061] [4351] [4641] [5075] [5511] [5801]
PVLP, shock and suction valve
Symbol
Description
Shock and suction valve for port A and/or B.
(Not adjustable).
Lifetime 200.000 actuations.
Technical Information
PVG 32 Proportional Valve Group
Modules symbols, description and code numbers
56 |
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals