PVG 32 sectional view
1
2
3
4
6
7
9
8
T P
M
A
LS
B A
12
13
11
10
14
16
17
15
T T
LS
B
LS
A
B A
P
T T
B
19
P
18
20
V310106.A
PVP
PVB
PVB
5
1. Pressure relief valve 11. Main spool
2. Pressure reduction valve for pilot oil supply 12. LS pressure limiting valve
3. Pressure gauge connection 13. Shock and suction valve, PVLP
4. Plug, open center 14. Pressure compensator
5. Orifice, closed center 15. LS connection, port A
6. Pressure adjustment spool 16. LS connection, port B
7. Plug, closed center 17. Suction valve, PVLA
8. LS connection 18. Load drop check valve
9. LS signal 19. Pilot oil supply for PVE
10. Shuttle valve 20. Maximum oil flow adjustment screws for A/B ports
Load sensing for variable displacement pump supply
The pump receives fluid directly from the reservoir through the inlet line. A screen in the inlet line
protects the pump from large contaminants.
Technical Information
PVG 32 Proportional Valve Group
General description
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802 | 9

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals