Characteristics for float position main spools
Characteristic of oil flow, spool travel and voltage
4.8 mm [0.19 in] spool displacement in direction A gives maximum oil flow to port A
4.8 mm [0.19 in] spool displacement in direction B gives maximum oil flow to port B
8 mm [0.32 in] spool displacement in direction B gives completely open float position A/B T.
The spools have 4.8 mm spool travel in direction A and 8 mm travel in direction B:
For more information regarding electrical actuation of float spools please see PVE series 4 Technical
Information, 520L0553.
Pressure drop A/B T at maximum spool travel within the proportional range (4.8 mm) [0.19 in]
Spools D and E have the same opening area for forward flow and return flow.
Spool E can give 100 l/min [26.4 US gal/min] pressure compensated oil flow due to a higher pressure
drop across spool E. This occurs during spool actuation only.
Technical Information
PVG 32 Proportional Valve Group
Technical characteristics
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802 | 43

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
BrandDanfoss
ModelPVG 32
CategoryControl Unit
LanguageEnglish

Related product manuals