EasyManuals Logo
Home>Danfoss>DC Drives>VLT 2800

Danfoss VLT 2800 Design Guide

Danfoss VLT 2800
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
1.13.9 Parameter Selection
Press [Menu] to start the Menu mode, which produces the
following readout in the display:
50.0 Hz
FREQUENCY
0 KEYB.&DISPLAY
Illustration 1.34 Menu Mode Display
Line 3 in the display shows the parameter group number
and name.
In Menu mode, the parameters are divided into groups.
Selection of parameter group is effected using the [< >]
keys.
The following parameter groups are accessible:
Group no. Parameter group
0 Operation & Display
1 Load & Motor
2 References & Limits
3 Inputs & Outputs
4 Special functions
5 Serial communication
6 Technical functions
When the required parameter group is selected, select the
parameter with the [+]/[ -] keys:
FREQUENCY
001 LANGUAGE
ENGLISH
50.0 Hz
Illustration 1.35 Select a Parameter
The third line of the display shows the parameter number
and name, while the status/value of the selected
parameter is shown in line 4.
Changing data
Regardless of whether a parameter is selected under the
Quick Menu mode or the Menu mode, the procedure for
changing data is the same. Press [Change Data] to change
the selected parameter, following which the underlining in
line 4 flashes on the display. The procedure for changing
data depends on whether the selected parameter
represents a numerical data value or a text value.
Changing a data value
If the selected parameter is a text value, change the text
value with the [+] or [-] key.
50.0 Hz
FREQUENCY
001 LANGUAGE
ENGLISH
Illustration 1.36 Change a Data Value
The bottom display line shows the value that is entered
(saved) when acknowledgment is given [OK].
Change of numeric data value
If the selected parameter is represented by a numerical
data value, select a digit with the [] or [] key.
50.0 Hz
SETUP
1
FREQUENCY
130 START FREQUENCY
09.0 HZ
Illustration 1.37 Change a Numeric Data Value - I
The selected digit can then be changed infinitely variably
with the [+] or [-] key:
50.0 Hz
SETUP
1
FREQUENCY
130 START FREQUENCY
10.0 HZ
Illustration 1.38 Change a Numeric Data Value - II
The selected digit is indicated by the digit flashing. The
bottom display line shows the data value that is entered
(saved) when signing off with [OK].
Introduction to VLT 2800
Design Guide
30 Danfoss A/S © Rev. May/2014 All rights reserved. MG27E402
1
1

Table of Contents

Other manuals for Danfoss VLT 2800