1 Introduction
1.1 Purpose of the Manual
This instruction manual provides information for safe instal-
lation and commissioning of the adjustable frequency
drive.
This instruction manual is intended for use by qualied
personnel.
Read and follow the instruction manual to use the
adjustable frequency drive safely and professionally, and
pay particular attention to the safety instructions and
general warnings. Keep this instruction manual available
with the adjustable frequency drive at all times.
VLT
®
is a registered trademark.
1.1.1
Intended Use
The adjustable frequency drive is an electronic motor
controller intended for:
Regulation of motor speed in response to system
feedback or to remote commands from external
controllers. A power drive system consists of the
adjustable frequency drive, the motor and
equipment driven by the motor.
System and motor status surveillance.
The adjustable frequency drive can also be used for motor
protection.
Depending on conguration, the adjustable frequency
drive can be used in stand-alone applications or form part
of a larger appliance or installation.
The adjustable frequency drive is allowed for use in
residential, industrial and commercial environments in
accordance with local laws and standards.
NOTICE!
In a residential environment, this product can cause
radio interference, in which case supplementary
mitigation measures can be required.
Foreseeable misuse
Do not use the adjustable frequency drive in applications
which are non-compliant with specied operating
conditions and environments. Ensure compliance with the
conditions specied in chapter 7 General Specications.
1.1.2
Abbreviations and Standards
Abbrevi-
ations
Terms SI units I-P units
a
Acceleration
m/s
2
ft/s
2
AWG American wire gauge
Auto Tune Automatic motor tuning
°C
Celsius
I Current A Amp
I
LIM
Current limit
IT line
power
Line power supply with star
point in transformer oating
to ground
Joule Energy J=N∙m ft-lb, Btu
°F
Fahrenheit
FC Adjustable frequency drive
f Frequency Hz Hz
kHz Kilohertz kHz kHz
LCP Local control panel
mA Milliampere
ms Millisecond
min Minute
MCT Motion Control Tool
M-TYPE Motor type dependent
Nm Newton meters in-lbs
I
M,N
Nominal motor current
f
M,N
Nominal motor frequency
P
M,N
Nominal motor power
U
M,N
Nominal motor voltage
PELV Protective extra low voltage
Watt Power
W
Btu/hr,
hp
Pascal Pressure
Pa =
N/m²
psi, psf,
ft of
water
I
INV
Rated inverter output current
RPM Revolutions per minute
s Second
SR Size related
T Temperature C F
t Time s s, hr
T
LIM
Torque limit
U Voltage V V
Table 1.1 Abbreviations and Standards
Introduction
VLT
®
HVAC Drive FC 102
4 Danfoss A/S © 08/2014 All rights reserved. MG11F522
1
1

Table of Contents

Other manuals for Danfoss VLT AHF 005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AHF 005 and is the answer not in the manual?

Danfoss VLT AHF 005 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AHF 005
CategoryDC Drives
LanguageEnglish

Related product manuals