3.1.12 Changing a Data Value
If the selected parameter shows a numeric data value,
change the selected data value with the [
] [
] navigation
keys and the [
] [
] navigation keys. Press [
] [
] keys to
move the cursor horizontally.
130BP069.10
1- 6*
113 RPM 1.78 A 1(1)
Load depen. setting
1 - 60 Low speed load
compensation
100%
Illustration 3.17 Changing a Data Value
Press the [
] [
] keys to change the data value. [
]
increases the data value, and [
] decreases the data value.
Place the cursor on the value to save and press [OK].
130BP070.10
1 - 60 Low speed load
compensation
1 0%
Load depen. setting 1- 6*
729RPM 6.21A 1(1)
6
Illustration 3.18 Saving a Data Value
3.1.13 Innitely Variable Change of
Numeric Data Value
If the selected parameter shows a numeric data value,
select a digit with [
] [
].
130BP073.10
635 RPM
1 - 71 Start Delay
00.0s
0.44 A 1 (1)
1- 7*
Start Adjustments
Illustration 3.19 Selecting a Digit
Change the selected digit innitely variably with [
] [
].
The cursor indicates the selected digit. Place the cursor on
the digit to save and press [OK].
130BP072.10
957RPM
1-71 High starting torque time
0. s
11.58A 1 (1)
1-7*Start Adjustments
4
Illustration 3.20 Saving
3.1.14 Value, Step by Step
Certain parameters can be changed step by step. This
applies to:
Parameter 1-20 Motor Power [kW].
Parameter 1-22 Motor Voltage.
Parameter 1-23 Motor Frequency.
The parameters are changed both as a group of numeric
data values and as numeric data values that are innitely
varying.
3.1.15 Readout and Programming of
Indexed Parameters
Parameters are indexed when placed in a rolling stack.
Parameter 15-30 Fault Log: Error Code to
parameter 15-32 Alarm Log: Time contain a fault log, which
can be read out. Select a parameter, press [OK], and press
the [
] [
] keys to scroll through the value log.
For example, parameter 3-10 Preset Reference is changed as
follows:
1.
Select the parameter, press [OK], and press [
] [
]
to scroll through the indexed values.
2. To change the parameter value, select the
indexed value and press [OK].
3.
Change the value by pressing [
] [
].
4. Press [OK] to accept the new setting.
5. Press [Cancel] to abort. Press [Back] to leave the
parameter.
3.1.16 How to Program on the Numerical
Local Control Panel
The following instructions are valid for the numerical LCP
(LCP 101).
The control panel is divided into 4 functional groups:
Numerical display.
Menu keys and indicator lights - changing
parameters and switching between display
functions.
Navigation keys and indicator lights.
Operation keys and indicator lights.
Programming VLT® AutomationDrive FC 361
20 Danfoss A/S © 03/2019 All rights reserved. MG06J202
33

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 361

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 361 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 361 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 361
CategoryDC Drives
LanguageEnglish

Related product manuals