Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 100 milliseconds to
25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps
the LED on until the next trigger pull.
See
page 298 in “References” for detailed instructions and examples for setting this fea-
ture.
$CLAGL00
Good Read LED Duration Setting =
Keep LED on until next trigger pull
Select Good Read LED Duration Setting
$CLAGL
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by three digits from the Alpha-
numeric characters in Appendix D, Keypad repre-
senting your desired character(s). End by scanning
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
003 = Good Read LED stays on for 300 msec.
NOTE: Indicators are dimmed during sleep.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD96 Series and is the answer not in the manual?

Datalogic PowerScan PD96 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD96 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals