ENTER/EXIT PROGRAMMING MODE WIRELESS FEATURES
266
POWERSCAN™ PD/PM96XX
RF ADDRESS STAMPING
These features allow configuration of source radio data inclusion.
Source Radio Address Transmission
Enables/disables the ability of source radio address information to be transmitted to the
host and, if so, at what position with respect to the label data. See
page 299 in “Refer-
ences” for detailed information and examples for setting this feature.
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and
radio address when address stamping is enabled.
NOTE: When included as a prefix, the source-radio ID is displayed after all
label formatting has been applied. The 6 byte hex address is sent as 12
ASCII characters, i.e., an address of 00 06 66 00 1A ED will be sent as
(shown in hex): 30 30 30 36 36 36 30 30 31 41 45 44
$CBTAS00
Source Radio Address Transmission =
Do Not Include
Source Radio Address Transmission = Prefix
$CBTAS01
NOTE: This feature only applies if "Source Radio Address Transmission" on
page 266
is enabled.
Set Source Radio Address Delimiter Character
$CBTAD
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Delimiter Character = 00 (no delimiter character)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD96 Series and is the answer not in the manual?

Datalogic PowerScan PD96 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD96 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals