REFERENCES
292
POWERSCAN™ PD/PM96XX
SCANNING FEATURES
Scan Mode
Selects the scan operating mode for the reader. Selections are:
Trigger Single:
When the trigger is pulled, scanning is activated until one of the follow-
ing occurs:
Stand Mode/Object Detection has elapsed
a label has been read
the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is
pulled, scanning starts and the product scans until the trigger is released, or a label is
read, or the maximum Stand Mode/Object Detection has elapsed.
Trigger Hold Multiple:
When the trigger is pulled, scanning starts and the product
scans until the trigger is released or Stand Mode/Object Detection has elapsed. Reading
a label does not disable scanning.
Double Read Timeout prevents undesired multiple
reads of the same label while in this mode.
Trigger Pulse Multiple:
When the trigger is pulled, continuous scanning is activated
until Stand Mode/Object Detection has elapsed or the trigger has been released and
pulled again.
Double Read Timeout prevents undesired multiple reads of the same label
while in this mode.
Flashing:
The reader flashes
1
on and off regardless of the trigger status. Flash rate is
controlled by
Flash On Time and Flash Off Time. When Flash is ON the reader reads con-
tinuously. When Flash is OFF scanning is deactivated.
Always On:
No trigger pull is required to read a bar code. Scanning is continually on.
Double Read Timeout prevents undesired multiple reads of the same label while in this
mode.
Stand Mode/Object Detection:
No trigger pull is required to read a bar code. Scanning
turns on automatically when an item is placed in reader's field of view. While in a stand
watch state, the reader illumination LED goes from dim to maximum bright.
Retained Trigger Hold Multiple:
Same as Trigger Hold Multiple but all decoded labels
are transmitted when the trigger is released. The labels can be sorted before transmis-
sion. When the reader is configured in Retained Trigger Hold Multiple, it is possible to
set the parameter
Multiple Labels Ordering by Code Symbology to specify the order multi-
ple labels are transmitted by symbology type.
To configure the code symbology order, choose the corresponding digits from the fol-
lowing table:
Table 20 - Multiple Labels Ordering by Code Symbology
1. Controlled by Flash On Time.
HEX VALUE CODE SYMBOLOGY HEX VALUE CODE SYMBOLOGY
0x00 = Any Type 0x20 = ISBN
0x01 = UPC-A 0x22 = Interleaved 2/5
0x02 = UPC-E 0x23 = Codabar

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD96 Series and is the answer not in the manual?

Datalogic PowerScan PD96 Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD96 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals