80 H-Class
Standard Calibration (continued)
Step
Action Displayed Message Comment
G
Observe the calibration
result.
CALIBRATION COMPLETE
Calibration was
successful.
;
If ‘Warning Low
Backing’ is displayed,
calibration was successful
(for possible messages
see Section 5.1).
H
Press ESC then EXIT to
return to READY.
When calibrating gap or
reflective media, press and
hold the FEED Key until at
least one label is output.
CALIBRATION COMPLETE
Followed by...
READY
The printer is now ready
for use.
5.2.2 Advanced Entry Calibration
Advanced Entry is an alternate calibration method for special-case media types, where
sensor readings are taken using different sampling algorithms and from a list of these
readings the best algorithm is selected for manual entry into the database.
;
Advanced Entry Calibration should be used only when Standard Calibration proves
unsuccessful. Also, before proceeding, ensure that the ADVANCED MENU is enabled
(see Section 4.2.4) and that the SENSOR TYPE is selected (see Section 4.2.1).
Calibrate the Media Sensor using the steps below: