System weight
Table 8. PowerEdge XR4000r system weight
System configuration Maximum weight (with all drives/SSDs)
Weight of chassis without sleds 7.96 kg (17.54 pound)
Weight of chassis with sleds and bezel and witness node 19.14 kg (42.20 pound)
Table 9. PowerEdgesystemweight handling recommendations
Chassis weight Description
40 pounds - 70 pounds Recommend two person to lift
70 pounds- 120 pounds Recommend three person to lift
121 pounds Recommend to use a server-lift
Witness cooling fan specifications
The PowerEdge XR4000r system supports one standard fan with Normal air flow (NAF) or Reverse air flow (RAF) for witness
sled cooling.
Table 10. Cooling fan specifications
Fan type Label color Label image
Standard (STD) fan (60
mm cable length)
No label
NOTE: The cooling fan installed in the chassis is used for optional witness sled cooling.
PSU specifications
The PowerEdge XR4000r system supports up to two AC or DC power supply units (PSUs).
Table 11. PSU specifications
PSU Class Heat
dissipation
(maximum
) (BTU/hr)
Frequency
(Hz)
Voltage AC DC Current (A)
High line
200240 V
Low line
100120 V
1800W
Mixed
Mode
Titaniu
m
6750 BTU/
hr
50/60 Hz
200 - 240 V
AC
1800W NA NA 10 A
6750 BTU/
hr
NA
240 V DC NA NA 1800 W 8.2 A
1400 W
Mixed
Mode
Platinu
m
5250 BTU/
hr 50/60 Hz
100 - 240 V
AC
1400 W 1050 W NA 12 A - 8 A
14 Technical specifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge XR4000r and is the answer not in the manual?

Dell PowerEdge XR4000r Specifications

General IconGeneral
BrandDell
ModelPowerEdge XR4000r
CategoryNetwork Hardware
LanguageEnglish

Related product manuals