Chapter 8 Load Cell Module AS02LC
8- 35
8_
(5) Alarm settings
8.5 Troubleshooting
8.5.1 Error Codes
Error
Code
Description
A
↔
D LED
indicator
ERROR LED
indicator
16#1605
Hardware failure OFF ON
16#1607
The external voltage is abnormal. OFF ON
16#1801
The external voltage is abnormal. OFF Blinking
16#1802
Hardware failure OFF
Blinking
16#1807
The driver board is abnormal. OFF
Blinking
16#1808
The weight measured by CH1 exceeds the maximum weight that
can be measured, or the voltage of SEN is incorrect.
Run: blinking
Stop: OFF
Blinking
16#1809
The weight measured by CH1 exceeds the maximum weight that
can be measured.
16#180A
CH1 is adjusted incorrectly.
16#180B
The weight measured by CH2 exceeds the maximum weight that
can be measured, or the voltage of SEN is incorrect.
16#180C
The weight measured by CH2 exceeds the maximum weight that
can be measured.
16#180D
CH2 is adjusted incorrectly.