EasyManua.ls Logo

Delta AS00SCM-A User Manual

Delta AS00SCM-A
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
AS Series Module Manual
3- 2
_3
3.1 Overview
This chapter describes the specifications for analog-to-digital modules, their operation, and their programming.
In this chapter, module refers to the analog-to-digital modules AS04AD-A, AS08AD-B, and AS08AD-C.
3.1.1 Characteristics
(1) Select a module based on its practical application.
AS04AD-A: Has four channels. A channel can receive either voltage or current input.
AS08AD-B: Has eight channels. A channel can receive voltage input.
AS08AD-C: Has eight channels. A channel can receive current input.
(2) High-speed conversion
Analog signals are converted to digital signals at a rate of 25 ms per channel.
(3) High accuracy
Conversion accuracy: The error range for both voltage input and current input is ±0.2% at ambient
temperature of 25° C. The number of voltage/current inputs that are averaged
is 100.
(4) Use the utility software to configure the module.
The HWCONFIG utility software is built into ISPSoft. You can set modes and parameters directly in
HWCONFIG without spending time writing programs to set registers to manage functions.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Delta AS00SCM-A and is the answer not in the manual?

Delta AS00SCM-A Specifications

General IconGeneral
ModelAS00SCM-A
CategoryNetwork Hardware
ManufacturerDelta
Product TypeEthernet Switch
Operating Temperature-10°C to 60°C
InterfaceEthernet
Ethernet10/100Base-T(X)

Summary

Chapter 1 Introduction

1.3 Installation

Provides step-by-step instructions for installing modules, removable terminal blocks, extension cards, and wiring modules, including notes on anti-vibration baffles.

Chapter 3 Analog Input Module AS04/08AD

3.3 HWCONFIG in ISPSoft

Explains how to use the HWCONFIG utility software for initial setup, checking module versions, online mode operations, and importing/exporting parameter files.

3.4 DIADesigner+ (Hardware Configuration)

Guides through using DIADesigner+ for hardware configuration, including initial setup, module addition, parameter setting, and logging in.

3.5 Troubleshooting

Provides troubleshooting information including error codes and procedures for common issues like hardware failure and abnormal external voltage.

Chapter 4 Analog Output Module AS04DA

4.3 HWCONFIG in ISPSoft

Explains the usage of HWCONFIG for initial setup, downloading parameters, checking module versions, online mode operations, and importing/exporting parameter files.

4.4 DIADesigner+ (Hardware Configuration)

Guides through the hardware configuration process using DIADesigner+, including initial setup, adding modules, parameter setting, and logging in.

4.5 Troubleshooting

Provides troubleshooting steps for error codes and common issues encountered with the analog output module.

Chapter 5 Analog Input/Output Module AS06XA

5.3 HWCONFIG in ISPSoft

Explains the use of HWCONFIG for initial setup, downloading parameters, checking module versions, online mode operations, and importing/exporting parameter files.

5.4 DIADesigner+ (Hardware Configuration)

Guides through the hardware configuration process using DIADesigner+, including initial setup, adding modules, parameter setting, and logging in.

5.5 Troubleshooting

Provides troubleshooting information including error codes and procedures for common issues like hardware failure and communication timeouts.

Chapter 6 Temperature Measurement Module AS04/06RTD

6.3 HWCONFIG in ISPSoft

Explains the use of HWCONFIG for initial setup, downloading parameters, checking module versions, online mode operations, and importing/exporting parameter files.

6.4 DIADesigner+ (Hardware Configuration)

Guides through hardware configuration using DIADesigner+, including initial setup, adding modules, parameter setting, and checking module versions.

6.5 Troubleshooting

Provides troubleshooting information including error codes and procedures for issues like hardware failure and abnormal external voltage.

Chapter 7 Temperature Measurement Module AS04/08TC

7.3 HWCONFIG in ISPSoft

Explains the use of HWCONFIG for initial setup, downloading parameters, checking module versions, online mode operations, and importing/exporting parameter files.

7.4 DIADesigner+ (Hardware Configuration)

Guides through hardware configuration using DIADesigner+, including initial setup, adding modules, parameter setting, and checking module versions.

7.5 Troubleshooting

Provides troubleshooting information including error codes and procedures for issues like hardware failure and communication timeouts.

Chapter 8 Load Cell Module AS02LC

8.3 Making Adjustments

Explains how to make adjustments to the weight measured by a cell to correspond to the digital value, covering steps to adjust points, LC wizard, and calibration commands.

8.4 HWCONFIG in ISPSoft

Guides the use of HWCONFIG for initial setup, checking module versions, online mode, importing/exporting parameter files, and parameter settings.

8.5 Troubleshooting

Provides troubleshooting information including error codes and procedures for issues like hardware failure and abnormal driver board.

Chapter 9 Serial Communication Module AS00SCM

9.7 Error Codes

Lists error flags and UD Link status codes stored in data registers, providing solutions for common errors when AS00SCM-A acts as a communication module or remote module.

Chapter 11 DeviceNet Master Scanner Module AS01DNET-A

Chapter 12 Positioning Module AS02/04

Chapter 13 IO-Link Communication Module AS04SIL

Chapter 14 High Speed Counter Module AS02HC

Related product manuals