EasyManuals Logo
Home>Delta>Servo Drives>ECMA-E 1315 Series

Delta ECMA-E 1315 Series User Manual

Delta ECMA-E 1315 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
ASDA-A2 Chapter 4 Panel Display and Operation
4-10 Revision February, 2017
4.4.2 JOG Mode
When it is in Parameter Mode, select P4-05 and follow the setting method below for JOG operation.
(1) Press the SET Key to display the speed value of JOG. The default value is 20r/min.
(2) Press UP or DOWN Key to adjust the desired speed value of JOG. It is adjusted to 100r/min
in the example.
(3) Press the SET Key to display JOG and enter JOG mode.
(4) When it is in JOG Mode, press UP or DOWN Key to enable the servo motor in forward or
reverse direction. The servo motor stops running as soon as the user stops pressing the key.
JOG operation is working only when it is Servo ON.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-E 1315 Series and is the answer not in the manual?

Delta ECMA-E 1315 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-E 1315 Series
CategoryServo Drives
LanguageEnglish

Related product manuals