Chapter 8 Parameters ASDA-A2
8-40 Revision February, 2017
P1-xx Basic Parameters
P1-00
PTT The Type of External Pulse Input
Address: 0100H
0101H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.1
Default
0x2
Control
Mode
PT
Unit
-
Range
0 ~ 0x1132
Data Size
16-bit
Format
Hexadecimal
Settings
Pulse Type
0: AB phase pulse (4x)
1: Clockwise (CW) and Counterclockwise (CCW) pulse
2: Pulse + symbol
Other setting: reserved
Filter Width
If the received frequency is much higher than the setting, it will be
regarded as the noise and filtered out.
Setting
Value
Min. pulse width*note1
(Low-speed filter
frequency)
Setting
Value
Min. pulse width*note1
(High-speed filter
frequency)
0 600ns (0.83Mpps) 0 150ns (3.33Mpps)
1 2.4us (208Kpps) 1 600ns (0.83Mpps)
2 4.8us (104Kpps) 2 1.2us (416Kpps)
3 9.6us (52Kpps) 3 2.4us (208Kpps)
4 No filter function 4 No filter function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-E 1315 Series and is the answer not in the manual?

Delta ECMA-E 1315 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-E 1315 Series
CategoryServo Drives
LanguageEnglish

Related product manuals