EasyManuals Logo
Home>Delta>Servo Drives>ECMA-E 1315 Series

Delta ECMA-E 1315 Series User Manual

Delta ECMA-E 1315 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
ASDA-A2 Chapter 4 Panel Display and Operation
4-12 Revision February, 2017
4.4.4 Digital Input Diagnosis Operation
Enter into the Digital Input Diagnosis Mode by the following setting methods. When the external
output signal DI1~DI8 is ON, the corresponding signal will be shown on the panel. It is displayed
by bit. When it shows bit, it means it is ON.
For example, if it shows 3FE1, E is in hexadecimal format, it will be 1100 when it transfers to binary
format. Then, DI6~DI8 is ON.
4.4.5 Digital Output Diagnosis Operation
Enter into the Digital Output Diagnosis Mode by the following setting methods. The output signal
DO1~DO5 is ON and the corresponding signal will be shown on the panel. It is displayed by bit.
When it shows bit, it means it is ON.
For example, if it shows 1F, F is in hexadecimal format, it will be 1111 when it transfers to binary
format. Then, DO1~DO4 is ON.
SET
DO
5
DO
4
DO
3
DO
2
DO
1
Corresponding
DO status
Binary code
The panel displays in
hexadecimal format
(Display in hexadecimal format)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-E 1315 Series and is the answer not in the manual?

Delta ECMA-E 1315 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-E 1315 Series
CategoryServo Drives
LanguageEnglish

Related product manuals