EasyManuals Logo
Home>Delta>Servo Drives>ECMA-E 1315 Series

Delta ECMA-E 1315 Series User Manual

Delta ECMA-E 1315 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #340 background imageLoading...
Page #340 background image
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-89
P1-82 VCMLPF
Filter Switching Time between P1-40 and P1-
81
Address: 01A4H
01A5H
Operational
Interface:
Panel / Software Communication
Related Section:
Default:
0
Control
Mode:
S
Unit:
msec
Range:
0 ~ 1000 (0: disable this function)
Data Size:
16-bit
Format:
Decimal
Settings:
0: Disabled
P1-83 VCMLPF Abnormal Analog Input Voltage Level
Address: 01A6H
01A7H
Operational
Interface:
Panel/Software Communication
Related Section:
Default:
0
Control
Mode:
S
Unit:
mV
Range:
0 ~ 12000 (0: disable this function)
Data Size:
16-bit
Format:
Decimal
Settings: When analog input voltage is over 50ms, AL.042 will occur. The
compared level for this parameter is the original analog input voltage
which has not been added by an offset value via parameter P4-22,
Analog Speed Input Offset.