ASDA-A2 Preface
Revision February, 2017 iii
Operation
 Before the operation, please change the parameter setting value according to the
needs. If it is not adjusted to the correct setting value, it is possible to lead to
malfunction of the machine or the operation might out of control.
 Before the machine starts to operate, please be ensured the emergency stop can be
activated anytime.
 When power on, please make sure the motor shaft stands still and will not operate
because of mechanical inertia or other causes.
 During the operation, it is prohibited to touch any rotating motor parts. Or it is
possible to cause personnel injury.
 In order to prevent any accident, please separate the couplings and belts of the
machine and isolate them. Then conduct the initial trial run.
 If users fail to operate the machine properly after the servo motor connects to the
equipment, it would cause the damage of the equipment and lead to the personnel
injury.
 In order to prevent the danger, it is strongly recommended to check if the motor can
operate normally without load first. Then, operate the motor with load.
 Do not touch the heat sink of the servo drive. Or it is possible to cause scald due to
the high temperature.
Maintenance and Inspection
 It is prohibited to touch the internal parts of the servo drive and servo motor. Or it is
possible to cause electric shock.
 It is prohibited to disassemble the panel of the servo drive when turning on the
power. Or it is possible to cause electric shock.
 Do not touch the ground terminal within 10 minutes after turning off the power. Or the
residual voltage may cause electric shock.
 Do not disassemble the motor. Or it is possible to cause electric shock or personnel
injury.
 Do not change the wiring when the power is on. Or it is possible to cause electric
shock or personnel injury.
 Only the qualified electrical and electronics professionals can install, wire and
maintain the servo drive and servo motor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-E 1315 Series and is the answer not in the manual?

Delta ECMA-E 1315 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-E 1315 Series
CategoryServo Drives
LanguageEnglish

Related product manuals