SNMP device monitoring capabilities SNMP configuration
Digi Connect Family and ConnectPort TS Family
127
n DIGIenterprise MIBs
l DIGI CONNECTDEVICE INFO MIB—A Digi enterprise MIB for handling and displaying basic
device information, such as firmware revisions in use, device name, IP network
information, memory use, and CPU statistics.
l DigiConnect Mobile Information MIB—A Digi enterprise MIB for handling and displaying
device information for mobile devices.
l Digi Connect Wireless LAN MIB—A Digi enterprise MIB for handling and displaying basic
device information for wireless devices.
l DIGI SERIAL ALARM TRAPS MIB—A Digi enterprise MIB for sending alarms as SNMP traps.
l Digi Login Traps MIB—A Digi enterprise MIB that indicates when users attempt to sign into
the device, and whether the attempt was successful.
l Digi Structures of Management MIB—A Digi enterprise MIB that provides data structures
for managing hosts and gateways on a network.
l Digi Connect Mobile Traps MIB—A Digi enterprise MIB for sending alarms as SNMP traps for
mobile devices.
l Digi Connectware Notifications MIB—This Digi enterprise MIB may be required by some
SNMP import facilities, as other MIBs may refer to it.
See Download a Digi MIB for instructions on downloading a Digi MIB from the Digi website.
SNMP configuration
You can configure basic network and serial configurations for Digi Connect and ConnectPort TS Family
devices through SNMP:
n Use a subset of standard MIBs for network and serial configuration. See Supported RFCs and
MIBs for more information on supported MIBS.
n Use Digi enterprise MIBs for device identification, alarm handling, and Digi Connect and
ConnectPort TS Family-specific configurations.
To use the MIBS, you must load MIBs into a network management station (NMS).
Note that some SNMP configuration settings can be configured only from the web or command line
interfaces. For example, to send alarms as SNMP traps:
n In the web interface, use the Configuration > Alarms > alarm > Alarm Destinations > Send
SNMP trap to following destination when alarm occurs option. See Alarms Configuration.
n In the command-line interface, use the set alarm option typescript. See the set alarm
command description in the Digi Connect® Family Command Reference on www.digi.com.
Note You cannot configure all network and serial configurations using SNMP. For more advanced
configuration settings, use the web or command-line interfaces.