EasyManuals Logo
Home>DigiTech>Music Pedal>RP360 XP

DigiTech RP360 XP User Manual

DigiTech RP360 XP
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
52
RP360 / RP360 XP
Calibrate Pedal
Selecting this system option initiates the
expression pedal calibration procedure This
procedure can be used to calibrate the built-in
expression pedal in the RP360XP, or an external
expression controller connected to the RP360, in
the event that it is not working correctly
Plexi-Drive 1
LOOPER READY
SYSTEM SETTINGS 4/4
CALIBRATE
PEDAL
FACTORY
RESTORE
FIRMWARE
VERSION
START START
v 1.1.0.0
To calibrate the RP360XP’s expression pedal:
1
Press the SYSTEM button�
2 Press either the SELECT knob or SYSTEM button repeatedly until the LCD display reads 4/4 in
the upper right-hand corner of the LCD display
3 Turn the EDIT 1 (CALIBRATE PEDAL) knob to initiate the calibration procedure
4 Press the SELECT knob to confirm the action�
5 The display should now prompt you to place the expression pedal in the toe down position
then press
FOOTSWITCH 3
6 The display should now prompt you to place the expression pedal in the toe up position then
press
FOOTSWITCH 3
7 You will now be prompted to adjust the sensitivity of the expression pedal’s V-Switch (RP360XP
only)� Press
FOOTSWITCH 1 to decrease the sensitivity and FOOTSWITCH 2 to increase the
sensitivity The Sensitivity is shown in the LCD display as a numeric value�
8 Test the V-Switch by pressing the expression pedal to the toe down position then applying extra
pressure on the toe� As the V-Switch is triggered the LCD display will read “ON” or “OFF”,
depending upon the state of the V-Switch� Repeat steps 7-8 to fine tune the calibration of the
V-Switch� You want the V-Switch to trigger consistently, yet not be overly sensitive, which would
cause accidental triggers�
9 When done, press FOOTSWITCH 3 to complete the calibration procedure and return to the
Performance state�
NOTE: If “Calibration error!” appears in the LCD display when performing the expression pedal
calibration procedure, repeat steps 5-8� Pressing the
BACK button at any time during the above
procedure will abort the procedure�

Table of Contents

Other manuals for DigiTech RP360 XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DigiTech RP360 XP and is the answer not in the manual?

DigiTech RP360 XP Specifications

General IconGeneral
BrandDigiTech
ModelRP360 XP
CategoryMusic Pedal
LanguageEnglish

Related product manuals