Inputs and outputs
Outputs
PORT CONTROL
Discrete Outputs (General Purpose Output 1-4)
User-Defined LED
Tap-changer control (Raise, Lower, Tap-to-Neutral)
Voltage Reduction Input 1 and 2
PMT Mode B Slave Input
Enable Histograms, Profiler, Events, or Alarms
User Forms 1-20
User Intermediate Equations 1-4
LoopShare Enabled
Leader/Follower Enabled
Soft ADD-AMP
AltConfig
Inputs
MODULE STATUS (CONTROL-PROCESSOR PERCEIVED
STATES)
Active Alarms
Status Indicators (Tapping Blocked, Reverse Power, etc.)
Control Function Status
Tap At Neutral
No Input Volt Detected
No Output Volt Detected
PMT Status
System Errors
MODULE CONTROL (STATES DECIDED UPON BY THE
CONTROL CPU)
Features Enabled (Events, Alarms, Histograms, Profiler)
Supervisory Active
Tap-To-Neutral Input Active
Analog Voltage Reduction 1 Input Active
Analog Voltage Reduction 2 Input Active
PMT Mode B Slave Input Active
Loop Share Enable
Leader Follower Enable
Loop Share Active
Port 1 Tagged
Port 2 Tagged
Port 3 Tagged
PORT STATUS
Port 1 (Physical Input states)
Drag Hand Reset On
Neutral Position
Blocking Relay
Discrete Inputs (General Purpose Inputs 1-4)
Tap Raise Switch Active
Tap Lower Switch Active
Supervisory Switch On
Power Switch is Internal
Power Switch is External
Control Function Switch Status (Auto, Manual, Off)
Port 1 PMT Mode B Master Output
Port 2 (Command from communications port 2)
Tap Raise
Tap Lower
Tap-To-Neutral
Features Enabled (Events, Alarms, Histograms, Profiler,
Loop Share, Leader Follower)
Digital Communications User Inputs (00 to 32)
Port 3 (Command from communications port 1 or 3)
Tap Raise
Tap Lower
STATUS ALARMS
All available Status Alarms
DATA ALARMS
All available Data Alarms
PORT CONTROL
Discrete Outputs (General Purpose Output 1-4)
User-Defined LED
Tap-changer control (Raise, Lower, Tap-to-Neutral)
Voltage Reduction Input 1 and 2
PMT Mode B Slave Input
Features Enabled (Histograms, Profiler, Events, Alarms, Loop
Share, Leader Follower, Soft ADD-AMP, AltConfig)
User Forms 1-20
User Intermediate Equations 1-4
96
CL-6 SERIES CONTROL INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS MN225016EN January 2016

Table of Contents

Other manuals for Eaton 600 A 15 kV class push-OP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton 600 A 15 kV class push-OP and is the answer not in the manual?

Eaton 600 A 15 kV class push-OP Specifications

General IconGeneral
BrandEaton
Model600 A 15 kV class push-OP
CategoryCables and connectors
LanguageEnglish

Related product manuals