Product information
Introduction
This document describes the operation, and maintenance
instructions for Eaton's Cooper Power™ series CL-6 series
control for voltage regulators. Refer to Service Information
MN225008EN VR-32 Voltage Regulator with Quik-Drive™
Tap-Changer Installation, Operation, and Maintenance
Instructions for installation and operation information on
Eaton's Cooper Power series voltage regulator.
Read this manual first
Read and understand the contents of this manual and
follow all locally approved procedures and safety practices
before installing or operating this equipment. Read and
understand the manual detailing the installation and
operation of the regulator used with this control.
Additional information
These instructions cannot cover all details or vari ations in
the equipment, procedures, or processes described nor
provide directions for meeting every possible contin gency
during installation, operation, or maintenance. For additional
information, please contact your Eaton representative.
Acceptance and initial inspection
This product is completely assembled, tested, and
inspected at the factory. It is carefully calibrated, adjusted,
and in good condition when accepted by the carrier for
shipment.
Upon receipt, inspect the carton for signs of damage.
Unpack the control and inspect it thoroughly for damage
incurred during shipment. If damage is discovered, file a
claim with the carrier immediately.
Handling and storage
Be careful during handling and storage of equipment to
minimize the possibility of damage.
Standards
Eaton's regulators are designed and tested in accordance
with the following standards:
IEEE Std. C37.90.1
-2012
Standard
IEEE Std. C37.90.2
-2004
Standard
IEEE Std. C57.13
-2008
Standard
IEEE Std. C57.15
-2009
Standard
IEEE Std. C57.91
-2011
Standard
IEEE Std. C57.131
-2012
Standard
EN 50081-2
EN 61000-4
IEC 60068-2
IEC 60214-1
IEC 610255-5
Quality standards
ISO 9001 Certified Quality Management System.
Description
The reliable CL-6 control from Eaton incorporates the
latest in digital technology to provide accurate, rapid, and
dependable control of a step-voltage regulator. Utilizing
surface-mount technology and low-power electronics, the
CL-6 control is CE (Commonwealth Europe) compliant. The
nameplate located on the control box defines the power
circuit.
The CL-6 control allows keypad programming, Metering-
PLUS™ status inquiries, flashcard uploading and
downloading, and multiple communication ports with
user-selectable DNP3 or 2179 protocol. LED indicators
provide instant information on alarm, communications, and
regulation condition status. A four-line display provides more
detailed information and further simplifies programming.
In addition, the CL-6 control is highly configurable and
ready for use in applications where either digital or analog
supervisory control and data acquisition (SCADA) is
required.
1
CL-6 SERIES CONTROL INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS MN225016EN January 2016

Table of Contents

Other manuals for Eaton Tandem ELF Current-Limiting Dropout Fuse

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Tandem ELF Current-Limiting Dropout Fuse and is the answer not in the manual?

Eaton Tandem ELF Current-Limiting Dropout Fuse Specifications

General IconGeneral
BrandEaton
ModelTandem ELF Current-Limiting Dropout Fuse
CategoryCables and connectors
LanguageEnglish

Related product manuals