Onderhoud
Onderhoudsrapport
26
Onderhoudsrapport R600
Project
Ketel type Project
Serienummer Adres
Bouwjaar Plaats
Nominale belasting (Hi) [kW] Datum
Nominaal vermogen (Hi) [kW] Technicus
Systeem
Waterdruk [bar]
Water pH [-]
Water hardheid [dºH]
Water chloridegehalte [mg/l]
Water ∆T vollast [ºC]
Water ∆p
ketel
[kPa]
Waterstroming [m
3
/h]
Pomp instelling [-]
Veiligheidsfuncties
Maximaalthermostaat instelling [ºC] Aanvoervoeler gecontroleerd
Temp. begrenzer instelling [ºC] Rookgasvoeler gecontroleerd
Min. gasdrukschakelaar instelling [mbar] Stromingsschakelaar gecontr.
Ontstekingstijd brander [sec]
Verbrandingsanalyse
100% belasting 50% belasting Min. belasting
Gasverbruik [m
3
/h] [m
3
/h] [m
3
/h]
Gasdruk [mbar] [mbar] [mbar]
CO
2
[%] [%] [%]
O
2
[%] [%] [%]
CO [ppm] [ppm] [ppm]
NOx [ppm] [ppm] [ppm]
T
omgeving
[ºC] [ºC] [ºC]
T
rookgas
[ºC] [ºC] [ºC]
T
water, aanvoer
[ºC] [ºC] [ºC]
T
water, retour
[ºC] [ºC] [ºC]
Ionisatiestroom [µA] [µA] [µA]
p
ventilator
[mbar] [mbar] [mbar]
p
boven brander
[mbar] [mbar] [mbar]
p
vuurhaard
[mbar] [mbar] [mbar]
Opmerkingen