EN Series Drives Manual
Drive
Model
External AC Line Fuse
Recommended Minimum
AC/PE Line Wire Gauge
EN-204
15 Amp 10
14 AWG
EN 208
20 Amp 10
12 AWG
EN-214
20 Amp 30
12 AWG
Drive Model
Volta ge Range
(VAC)
Phasing
Frequency ( )
Inrush Current (Amps)
1st Cycle 2nd Cycle
EN 204 90-264
I 0
47-63 140 (8 ms) 50 (8 me)
EN-208 90-264
1 0 47-63
140 (8 ms) 50 (8 me)
EN-214 90-264 I or 3 0 47 63 100 (5 ms) 30
40 (5ms) 30
22
Note: Per UL requirements, this product is suitable for use on a circuit
The four position AC power connector (J1) is located on top of the drive. The
wiring diagram below shows single and three phase connections. EN-204, EN-
208 use only Ll and L2. L3 is connected on EN-214 drives using three phase
power.
by 20%.
Table 4 AC Power Specifications
The Protective Earth (PE) wire connection is mandatory for
fused or interrupted by any means. Failure to follow proper PE
wiring can cause death or serious injury.
AC Input Power Connections
The EN-204 and EN-208 drives require 90 to 264 VAC single phase power. The
EN-214 can operate with single or three phase 90 to 264 VAC. If single phase
power is used with the EN-214, you must de-rate the output power available
human safety and proper operation. This connection must not be
capable of delivering not more than 5000 RMS symmetrical amperes,
240 Volts maximum.
Table 3 AC Fusing and Wire Gauge Sizes